Skip to Content
Merck
  • Simultaneous determination of volatile organic compounds and carbonyls in mainstream cigarette smoke using a sorbent cartridge followed by two-step elution.

Simultaneous determination of volatile organic compounds and carbonyls in mainstream cigarette smoke using a sorbent cartridge followed by two-step elution.

Journal of chromatography. A (2013-09-24)
Shigehisa Uchiyama, Takuya Tomizawa, Yohei Inaba, Naoki Kunugita
ABSTRACT

We developed a simple method for the simultaneous determination of volatile organic compounds (VOCs) and carbonyls in the mainstream cigarette smoke using a sorbent cartridge at ambient temperature without the traditional cryogenic impinger. A sorbent cartridge is installed between intake filter and the pump of the smoking machine. Collection of cigarette mainstream smoke is performed according to the Canadian Intense regime or the ISO regime. As adsorbent, Carboxen 572 (CX-572) is the most suitable for collection of VOCs and carbonyls in the mainstream cigarette smoke. Elution of VOCs and carbonyls from CX-572 is performed by the two-step elution with carbon disulfide and methanol. VOCs are eluted by first elution with carbon disulfide and carbonyls are eluted by second elution with methanol. For VOCs, a portion of eluate is analyzed by gas chromatography-mass spectrometry. For carbonyls, a portion of eluate is derivatized with enriched 2,4-dinitrophenylhydrazine solution and analyzed by high-performance liquid chromatography. Measurement values by CX-572 cartridge method are very close to those obtained by traditional impinger method except for 2-butanone. Impinger methods use 2,4-dinitrophenylhydrazine solution containing 50% water and 2-butanone-DNPhydrazone may be hydrolyzed with water. In the CX-572 method, the hydrolysis of 2-butanone is prevented because the eluate solution contains no water. CX-572 method can measure cigarette smoke resulting from not only one whole cigarette but also from one puff volume because of its high sensitivity and simple operation.

MATERIALS
Product Number
Brand
Product Description

Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 564, 20-45 mesh, pack of 144 × 290 mg
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler