Direkt zum Inhalt
Merck
  • Levonorgestrel, medroxyprogesterone and progesterone cause a concentration-dependent reduction in endometrial cancer (Ishikawa) cell density, and high concentrations of progesterone and mifepristone act in synergy.

Levonorgestrel, medroxyprogesterone and progesterone cause a concentration-dependent reduction in endometrial cancer (Ishikawa) cell density, and high concentrations of progesterone and mifepristone act in synergy.

Anticancer research (2009-05-06)
Bjørn T Moe, Anne B Vereide, Anne Orbo, Ragnhild Jaeger, Georg Sager
ZUSAMMENFASSUNG

Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on human endometrial cancer (Ishikawa) cells. Supraphysiological concentrations of progesterone (PG) and high concentrations of LNG and MPA were employed to determine the order of potency in reducing cell density. The order of potency was LNG>MPA>PG with respective 50% inhibitory concentrations (IC(50)) of 3.9+/-0.4, 30.4+/-3.4 and 45.3+/-2.7 microM. Mifepristone (MF) is a potent antiprogestin, but was unable to antagonize the PG-induced cell density reduction. For MF concentrations from 0.2 to 70 microM alone, a PG-mimetic effect was observed with an IC(50) value of 19.0+/-1.7 muM. When PG and MF were combined, a marked reinforcement of the effect was seen. These observations indicate that extranuclear initiated signaling pathways are involved in the reduction of endometrial cancer cells exposed to high concentrations of PG and MF.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Supelco
ORBO Aktiviertes Kieselgel-Röhrchen, GFF,F,F separators, O.D. × L 7 mm × 100 mm, pkg of 50 ea
Supelco
ORBO Carboxen-564 Röhrchen, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Beschichteter ORBO 80 Filter, with cassettes: no, filter O.D. 37 mm, pkg of 25 ea
Supelco
ORBO Aktiviertes Kieselgel-Röhrchen, W,W,F separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
ORBO 43 Supelpak-20 speziell behandelte Amberlite XAD®-2 (20/40), 100/50 mg, W,W,W (specially treated) separators, O.D. × L 8 mm × 100 mm, pkg of 50 ea
Supelco
ORBO Aktiviertes Kieselgel-Röhrchen, W,W,F separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
ORBO 49P (OVS) Supelpak-20 speziell behandelt Amberlite XAD®-2 (20/40), 270/140 mg, RC,GFF,F,F (specially cleaned) separators, O.D. × L 13-8 mm × 75 mm , OSHA Versatile Sampler (OVS) Tube, pkg of 10 ea
Supelco
ORBO 402 Tenax® TA speziell behandelt (35/60), 100/50 mg, W,W,W separators, O.D. × L 8 mm × 100 mm, pkg of 50 ea
Supelco
ORBO Carboxen-564 Röhrchen, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group Vinyl acetate
Supelco
ORBO Amberlite XAD-2 Röhrchen, W,W,W separators, O.D. × L 8 mm × 110 mm, pkg of 50 ea
Supelco
ORBO Aktiviertes Kieselgel-Röhrchen, W,W,W separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
Beschichteter ORBO 80 Filter, with cassettes unassembled
Supelco
ORBO Amberlite XAD-4 Röhrchen, RC,GFF,F,F (specially cleaned) separators, O.D. × L 13-8 mm × 75 mm , OSHA Versatile Sampler (OVS), pkg of 10 ea
Supelco
ORBO 23 2-HMP auf Amberlite XAD®-2 (20/40), 120/60 mg, W,W,W separators, O.D. × L 6 mm × 85 mm, pkg of 25 ea
Supelco
ORBO 24 2-HMP auf Amberlite XAD®-2 (20/40), 150/75 mg, W,W,W separators, O.D. × L 6 mm × 105 mm, pkg of 25 ea