  • High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

High-throughput automatic flow method for determination of trace concentrations of aluminum in dialysis concentrate solutions using salicylaldehyde picolinoylhydrazone as a turn-on fluorescent probe.

Talanta (2014-12-02)
Arnau Garau, Miquel Oliver, María Rosende, Manuel P Mánuel-Vez, Manuel Miró
ZUSAMMENFASSUNG

A simple and expedient flow-based assembly capitalizing on programmable flow is herein proposed for reliable determination of trace level concentrations of aluminum as a potential contaminant in dialysis concentrate solutions without any prior sample clean-up/preconcentration procedure. Using salicylaldehyde picolinoylhydrazone in weakly acidic media as a turn-on fluorescent probe, the manifold is devised to handle three samples concurrently in stopped-flow reaction mode for simultaneous improvement of the analytical sensitivity and sample throughput. Analytical parameters influencing the sensitivity and repeatability of the assays, namely, probe concentration, reaction temperature and reaction time were investigated using a multivariate optimization protocol composed of a full factorial screening design followed by a Doehlert matrix model. The analysis of the Pareto chart and surface response revealed that the reaction time and amount of fluorescent probe were critical parameters for reliable assays of aluminum at the low ng mL(-1) level. Under the optimized chemical and physical variables, a detection limit of 1.1ngmL(-1) Al(III) at the 3s(blank) level, relative standard deviations better than 1.0%, a dynamic linear range of 5.0-80 ng mL(-1) and a sample throughput up to 25 h(-1) were obtained with no need for either sample preconcentration or the use of organized supramolecular systems. Demonstrated with the analysis of hemodialysis and peritoneal concentrate solutions, and dialysis waters, the flow-through method copes with the requirements of regulatory bodies (e.g., European Pharmacopeia) for quality control of aluminum in high salinity containing dialysis concentrates.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Essigsäure, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Essigsäure, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Essigsäure, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Essigsäure -Lösung, suitable for HPLC
Sigma-Aldrich
Essigsäure, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Hydrazin -Lösung, 35 wt. % in H2O
USP
Eisessig, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Essigsäure, ≥99.5%, FCC, FG
Sigma-Aldrich
Essigsäure, natural, ≥99.5%, FG
Sigma-Aldrich
5α-Androstan-17β-ol-3-on, ≥97.5%
Sigma-Aldrich
Hydrazin -Lösung, 1.0 M in THF
Sigma-Aldrich
Hydrazin -Lösung, 1.0 M in ethanol
Sigma-Aldrich
5α-Androstan-17β-ol-3-on, purum, ≥99.0% (TLC)
Supelco
Essigsäure, analytical standard
Sigma-Aldrich
Hydrazin -Lösung, 1 M in acetonitrile
Sigma-Aldrich
2-Picolinsäure-ethylester, 99%
Sigma-Aldrich
Essigsäure-12C2, 99.9 atom % 12C
Supelco
5α-Androstan-17β-ol-3-on, VETRANAL®, analytical standard
Millipore
Bifido Selektives Supplement B, suitable for microbiology