Direkt zum Inhalt
Merck

101052

Sigma-Aldrich

2,3,4,5,6-Pentafluor-benzylbromid

99%

Synonym(e):

α-Brom-2,3,4,5,6-pentafluor-toluol, Brommethyl-pentafluorbenzol

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
C6F5CH2Br
CAS-Nummer:
Molekulargewicht:
260.99
Beilstein:
647808
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352100
PubChem Substanz-ID:
NACRES:
NA.22

Assay

99%

Brechungsindex

n20/D 1.471 (lit.)

bp

174-175 °C (lit.)

mp (Schmelzpunkt)

19-20 °C (lit.)

Dichte

1.728 g/mL at 25 °C (lit.)

SMILES String

Fc1c(F)c(F)c(CBr)c(F)c1F

InChI

1S/C7H2BrF5/c8-1-2-3(9)5(11)7(13)6(12)4(2)10/h1H2

InChIKey

XDEPVFFKOVDUNO-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Derivatisierungsmittel für GC-Analyse von polyfunktionellen Thiolen.
Zur Herstellung von Pentafluorbenzylestern organischer Säuren zur Bestimmung durch Kapillaranalyse und GC. Auch zur Derivatisierung von N-7-substituierten Guaninaddukten von DNA zur Bestimmung durch GC-Elektronenfallen-MS verwendbar.

Piktogramme

Exclamation mark

Signalwort

Warning

Gefahreneinstufungen

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Zielorgane

Respiratory system

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 3

Flammpunkt (°F)

181.4 °F - closed cup

Flammpunkt (°C)

83 °C - closed cup

Persönliche Schutzausrüstung

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Laura Mateo-Vivaracho et al.
Journal of chromatography. A, 1121(1), 1-9 (2006-05-09)
A fast and automated method for the analysis at ng L(-1) level of aroma-powerful polyfunctional thiols has been developed and applied to wine. The sample is just poured in a 20 mL vial and its vapour extracted with a poly(dimethylsiloxane)-divinylbenzene
Journal of Chromatography A, 539, 232-232 (1991)
M Saha et al.
Journal of chromatography. A, 712(2), 345-354 (1995-10-13)
A 112-micrograms sample of DNA was spiked with 103 pg of N7-(2'-hydroxyethyl)guanine and 100 pg of N7-(2'-hydroxyethyl-d4)guanine, the internal standard. The sample was subjected to the following sequence of steps: heating at 100 degrees C, precipitation of the DNA with
Yan Li et al.
Frontiers in bioengineering and biotechnology, 7, 394-394 (2019-12-24)
The main challenges in multienzymatic cascade reactions for CO2 reduction are the low CO2 solubility in water, the adjustment of substrate channeling, and the regeneration of co-factor. In this study, metal-organic frameworks (MOFs) were prepared as adsorbents for the storage
D H Fisher et al.
Journal of chromatography, 452, 51-60 (1988-10-28)
The following sequence of analytical steps was used to determine the amount of 5-methylcytosine (mol-%) in calf thymus and human lymphocyte DNA:acid hydrolysis of the DNA, derivatization (pentafluorobenzyl bromide, solid phase extraction, pivalic anhydride), internal standard addition, solid phase extraction

Artikel

DNA damage and repair mechanism is vital for maintaining DNA integrity. Damage to cellular DNA is involved in mutagenesis, the development of cancer among others.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.