Passa al contenuto
Merck
Tutte le immagini(2)

Key Documents

GF17347282

Nickel

foil, not light tested, 148x300mm, thickness 0.003mm, 99.95%

Sinonimo/i:

Nickel, NI000215

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
Ni
Numero CAS:
Peso molecolare:
58.69
Numero MDL:
Codice UNSPSC:
12141729
ID PubChem:
NACRES:
NA.23

Saggio

99.95%

Forma fisica

foil

Produttore/marchio commerciale

Goodfellow 173-472-82

Resistività

6.97 μΩ-cm, 20°C

Misura × spessore

148 x 300 mm × 0.003 mm

P. eboll.

2732 °C (lit.)

Punto di fusione

1453 °C (lit.)

Densità

8.9 g/mL at 25 °C (lit.)

Stringa SMILE

[Ni]

InChI

1S/Ni
PXHVJJICTQNCMI-UHFFFAOYSA-N

Descrizione generale

For updated SDS information please visit www.goodfellow.com.

Note legali

Product of Goodfellow

Pittogrammi

Exclamation markHealth hazard

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Carc. 2 - Skin Sens. 1 - STOT RE 1

Codice della classe di stoccaggio

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 1

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

R J Schulz et al.
Physics in medicine and biology, 35(11), 1563-1574 (1990-11-01)
The thermal defects of A-150 plastic and graphite referenced to aluminium were determined for 800 keV protons scattered by a 2 micron nickel foil (mean transmitted energy = 550 keV). Composite cores of Al/A-150, graphite/A-150 and Al/graphite which could be
Kwanghyun Yoo et al.
Nanotechnology, 24(20), 205302-205302 (2013-04-20)
We firstly introduce a facile method for the site-specific direct physical exfoliation of few-layer graphene sheets from cheap and easily enlargeable graphite grown on a Ni foil using an optimized polydimethylsiloxane (PDMS) stamp. By decreasing the PDMS cross-linking time, the
G E van Dorssen et al.
Journal of X-ray science and technology, 3(2), 109-117 (1992-01-01)
The structure of Ni-C multilayer and single nickel layer samples has been analyzed before and after annealing, using two techniques: fluorescence EXAFS (F1EXAFS) at the Ni-K. edge and CuKα reflection. Annealing at a temperature of 450°C resulted in a change
F E Cecil et al.
The Review of scientific instruments, 81(10), 10D326-10D326 (2010-11-09)
We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors
W K Winnett et al.
Talanta, 41(10), 1627-1630 (1994-10-01)
A modification of the sample introduction system for combustion total organic carbon analyzers is presented where sample is sprayed into the instrument. Thermally created sprays and nebulizer sprays are discussed. It is shown that spray introduction gives more symmetric signals

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.