ECM557
QCM Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Fabricant/nom de marque
Chemicon®
QCM
Niveau de qualité
Technique(s)
cell based assay: suitable
Méthode de détection
colorimetric
Description générale
Leukocytes patrol the vascular system. They must migrate across endothelial barriers in order to recruit to sites of inflammation. This process involves a multistep cascade consisting of leukocyte rolling, adhesion, and transmigration. A quantitative assay for leukocyte transendothelial migration has been described using a modified Boyden chamber system (Roth et al. 1995, Ding et al. 2000). The Boyden chamber system is a two chamber system with a porous membrane providing an interface between these two chambers. Endothelial cells are cultured on top of the porous membrane that is coated with an extracelluar matrix (ECM) protein. Once a confluent layer of cells is established, leukocytes are then added onto the endothelial monolayer. Leukocyte migration across the endothelium is determined by measuring the number of cells that migrate between the endothelial cells, through the porous membrane, to the lower chamber.
Millipore′s Colorimetric QCM Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium. The assay is designed with a 3 μm pore size cell culture insert, appropriate for most leukocyte migration. The upper side of the cell culture insert is coated with fibronectin to support the optimal attachment and growth of endothelial cells. The assay allows investigators to evaluate the effects of various factors that influence the transendothelial process.
Precoated cell culture inserts are provided in the Millipore QCM Leukocyte Transendothelial Cell Migration Assay to significantly reduce assay time. Additionally, the assay allows quantitative analysis of leukocyte migration. Following incubation of leukocytes with the endothelial cell layer, migratory cells are stained and quantified with WST-1 reagent and measured using a spectrophotometer. Absorbance correlates with cell migration.
Precoated cell culture inserts are provided in the Millipore QCM Leukocyte Transendothelial Cell Migration Assay to significantly reduce assay time. Additionally, the assay allows quantitative analysis of leukocyte migration. Following incubation of leukocytes with the endothelial cell layer, migratory cells are stained and quantified with WST-1 reagent and measured using a spectrophotometer. Absorbance correlates with cell migration.
Application
Research Category
Cell Structure
Cell Structure
Results of the assay may be illustrated graphically using a bar chart to display optical density (OD) values at 420 - 480 nm.
Additional migration may also be induced or inhibited in test wells through the addition of cytokines or other pharmacological agents.
Figures 2 and 3 demonstrate typical migration results. One should use the data for reference only. This data should not be used to interpret actual assay results.
Additional migration may also be induced or inhibited in test wells through the addition of cytokines or other pharmacological agents.
Figures 2 and 3 demonstrate typical migration results. One should use the data for reference only. This data should not be used to interpret actual assay results.
This Colorimetric QCM Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium.
Conditionnement
24 Assays
Composants
1. Migration Test Plate: (Part No. CS202626) Two 24-well culture plates, each containing 12 human fibronectin-coated cell culture inserts (3 μm pore size), sufficient for the evaluation of 24 test samples
2. TNFα: (Part No. 2004167) One tube - 20 μL at 0.1 mg/mL
3. Cell Stain Solution: (Part No. 20294) One vial - 10 mL
4. WST-1 Reagent: (Part No. CS201370) One vial.
5. Electro Coupling Solution: (Part No. CS201382) One vial - 5 mL.
6. 96 well Stain Quantitation Plate: (Part No. 2005870) One plate.
7. Forceps: (Part No. 10203) 1 pair
2. TNFα: (Part No. 2004167) One tube - 20 μL at 0.1 mg/mL
3. Cell Stain Solution: (Part No. 20294) One vial - 10 mL
4. WST-1 Reagent: (Part No. CS201370) One vial.
5. Electro Coupling Solution: (Part No. CS201382) One vial - 5 mL.
6. 96 well Stain Quantitation Plate: (Part No. 2005870) One plate.
7. Forceps: (Part No. 10203) 1 pair
Stockage et stabilité
The kit is packaged in two individual boxes. ECM557-1 contains components that upon arrival should be stored at 2° to 8°C. ECM557-2 contains TNFα , WST-1, and Electro Coupling Solution that upon arrival should be stored at -20°C. Please refer to k
Informations légales
Accutase is a registered trademark of Innovative Cell Technologies, Inc.
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Clause de non-responsabilité
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial
Code de la classe de stockage
10 - Combustible liquids
Classe de danger pour l'eau (WGK)
WGK 3
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique