Direkt zum Inhalt
Merck

CGW303S03

Millipore

Polysep II, 1,0/0,2 µm nominal, Kartusche

pore size 1.0/0.2 μm, cartridge nominal length 30 in. (75 cm), Code 0 (2-222; O-rings)

Synonym(e):

Polysep II Cartridge Filter 30 in. 1.0/0.2 μm Code 0

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806
eCl@ss:
32031610

Materialien

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene
polypropylene support (Spun bonded)
silicone seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets EU framework regulation [1935/2004/EC] (all component materials; regarding materials and articles intended to contact food)
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

non-sterile

Kompatibilität mit Sterilisationsverfahren

autoclavable compatible
steam-in-place compatible

Produktlinie

Polysep

Leistungsmerkmale

hydrophilic

Hersteller/Markenname

Polysep

Parameter

3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C

Methode(n)

prefiltration: suitable

Länge

30 in.

Breite

2.7 in.

Nennlänge Kartusche

30 in. (75 cm)

Durchmesser

7.1 cm (2.8 in.)

Filtrationsfläche

1.38 m2

Verunreinigungen

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Gravimetrisch bestimmte extrahierbare Substanzen

≤420 mg/cartridge

Matrix

Polysep II

pore size

1.0/0.2 μm nominal pore size
1.0/0.2 μm pore size

Aufnahme

sample type liquid
sample type groundwater

Kartuschencode

Code 0 (2-222; O-rings)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Device Configuration: Filterelement

Leistungsmerkmale und Vorteile

Format: Double Layer

Verpackung

Leicht zu öffnender Doppelbeutel

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the first page of Visual Inspection Guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Angaben zur Herstellung

Sanitization Protocol
30 min mit 80 °C heißem Wasser
Sterilization Method
10 Autoklaven- oder In-situ-Dampfsterilisationszyklen von 30 min bei 121 °C
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥15 l Wasser
Gravimetric Extractables: after 24 hours in water at controlled room temperature

Rechtliche Hinweise

Polysep is a trademark of Sigma-Aldrich Co. LLC

Sie haben nicht das passende Produkt gefunden?  

Probieren Sie unser Produkt-Auswahlhilfe. aus.

Piktogramme

Flame

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Flam. Sol. 1

Lagerklassenschlüssel

4.1B - Flammable solid hazardous materials

WGK

WGK 2


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.