Accéder au contenu
MilliporeSigma

Assessment of polycrystalline graphites as sorbents for solid-phase microextraction of nonionic surfactants.

Journal of chromatography. A (2000-08-19)
R Aranda, P Kruus, R C Burk
RÉSUMÉ

Two polycrystalline graphites (pencil lead and glassy carbon) were used as sorbents for solid-phase microextraction of a nonionic alkylphenol ethoxylate surfactant (Triton X-100). Analyses were performed by reversed-phase HPLC-fluorescence detection. The presence of the benzene ring in the congeners of Triton X-100 also allowed their direct detection at lambda(ex) = 230 nm and lambda(em) = 310 nm. Variables such as time of adsorption, time of desorption and concentration of surfactant in water were evaluated. The method limit of detection was found to be 0.5 microg/l for Triton X-100, with a linear dynamic range of 0.5-150 microg/l. Results were compared to those obtained using polymeric fibers such as PDMS/DVB and Carbowax/TPR. The chemical resistance and low cost of the polycrystalline graphites are advantageous over commercially available SPME fibers.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
GC Stationary Phase, phase Triton X-100, bottle of 50 g