GE28-9909-46
Superdex® 200 Increase 3.2/300
column L × I.D. 30 cm × 3.2 mm, 8.6 μm particle size
About This Item
Produits recommandés
Matériaux
glass column
titanium frit
Gamme de produits
Superdex®
Durée de conservation
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Poids mol.
10000-600000 Da (globular proteins)
Conditionnement
1 ea of
Paramètres
<0.15 ml/min flow rate
3.0 Mpa (652 psi)
4-50 mL sample volume
Volume du lit
~2.4 mL
Colonne, L × D.I.
30 cm × 3.2 mm
Matrice
agarose-dextran composite
polymeric
Taille des particules
8.6 μm
cleaning
1-14
working range
3-12
Technique de séparation
size exclusion (SEC)
Catégories apparentées
Description générale
Publication
Adéquation
Stockage et stabilité
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Pressure is generated by the flow through the chromatographic system. For optimal chromatography functionality, it is important to understand the principle of the pressure drop over the different parts of a system.
Protocoles
Superdex from GE Healthcare are SEC media consisting of a composite base matrix of dextran and agarose. This page shows how to perform a separation with a superdex column.
Samples for chromatographic purification should be clear and free from particulate matter. Simple steps to clarify a sample before beginning purification will avoid clogging the column, can reduce the need for stringent washing procedures, and can extend the life of the chromatographic medium.
Samples for chromatographic purification should be clear and free from particulate matter. Simple steps to clarify a sample before beginning purification will avoid clogging the column, can reduce the need for stringent washing procedures, and can extend the life of the chromatographic medium.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique