Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

M7438

Sigma-Aldrich

Mimetic Orange 3 PIKSI Column

suspension

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151817
NACRES:
NA.56

forma

suspension

Nível de qualidade

Condições de expedição

wet ice

temperatura de armazenamento

2-8°C

Aplicação

Mimetic columns are used in protein chromatography, affinity chromatography and dye resins. Mimetic columns have been used in studies to develop anti-inflammatory therapeutics.

Pictogramas

Flame

Palavra indicadora

Warning

Frases de perigo

Declarações de precaução

Classificações de perigo

Flam. Liq. 3

Código de classe de armazenamento

3 - Flammable liquids

Classe de risco de água (WGK)

WGK 1

Ponto de fulgor (°F)

95.0 °F - closed cup

Ponto de fulgor (°C)

35 °C - closed cup

Equipamento de proteção individual

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

K Clark et al.
FEBS letters, 471(2-3), 182-186 (2000-04-18)
Integrin alpha4beta1 is a major leukocyte adhesion receptor that is a key target for the development of anti-inflammatory therapeutics. With the dual long-term goals of developing a reagent for use in high-throughput inhibitor screening assays and for crystallisation trials and
Tsutomu Arakawa et al.
Protein expression and purification, 63(2), 158-163 (2008-10-14)
MEP HyperCel resin, one of the Protein-A mimetic columns, is designed to bind antibodies at physiological pH and elutes the bound antibodies at mildly acidic pH. We have tested aqueous arginine solution for washing and elution of the resin. To
S J Burton
Methods in molecular biology (Clifton, N.J.), 11, 91-103 (1992-01-01)
Dye-ligand affinity chromatography is performed with an adsorbent consisting of a solid support matrix to which a dye has been cova-lently bonded. The protein mixture is passed through a packed bed of adsorbent that selectively binds proteins that are able
C R Lowe et al.
Trends in biotechnology, 10(12), 442-448 (1992-12-01)
Affinity chromatography has been extensively refined over the past few years to meet the more stringent criteria being placed on recombinant proteins as therapeutic products. New developments in the design of selective and stable ligands for affinity chromatography are establishing