Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

GE27-9267-01

illustra RTG RT-PCR Beads, 0.2 ML

Cytiva 27926701, liquid

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
55101520
NACRES:
NA.55

forma

liquid

fabricante/nome comercial

Cytiva 27926701

cor

colorless

Descrição geral

Ready-To-Go RT-PCR Beads are stable at room temperature and designed for performing single-tube one-step reverse transcription-PCR. Each room-temperature-stable bead contains M-MuLV Reverse Transcriptase, RNase Inhibitor, buffer, nucleotides, and Taq DNA Polymerase. The only additional reagents required are water, template RNA, and primers. The reagents are optimized for full-length cDNA synthesis to >7.5 kb and optimal sensitivity from PCR.

The Ready-To-Go Bead format significantly reduces the number of pipetting steps, thereby increasing reproducibility of the RT-PCR technique and minimizing risk of contamination and RNA degradation. Ready-To-Go RT-PCR Beads are provided in either thin walled 0.5 ml or 0.2 ml tubes compatible with most thermocyclers. The 0.2 ml tubes come assembled in a 96-well (8 × 12) plate format that allows individual strips of eight tubes to be easily removed. This flexibility allows use of either the entire 96-well plate, strips of eight or individual 0.2 ml tubes. Each package of Ready-To-Go RT-PCR Beads contains: RT-PCR beads, control reactions and pd(N)6 and oligo(dT) cDNA primers.

Características e benefícios

Pre-dispensed, freeze-dried beads that include the reagents necessary for one-step reverse transcription-PCR* with high sensitivity and reproducibility.

  • Preformulated, predispensed, single-dose, ambient-temperature-stable beads ensure greater reproducibility between reactions, minimize pipetting steps, and reduce the potential for pipetting errors and contamination.
  • Optimized as a one-tube, one-step RT-PCR* reaction for both cDNA synthesis and PCR.
  • Each lot of RT-PCR Beads is function tested for its ability to generate highly specific PCR products to ensure lot-to-lot reproducibility
  • For highly reproducible one-step reverse transcription-PCR.*

Armazenamento e estabilidade

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Nota de análise

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informações legais

illustra is a trademark of Cytiva

Código de classe de armazenamento

12 - Non Combustible Liquids


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Artigos

This page shows PCR and RT-PCR amplification troubleshooting.

Protocolos

Nucleic Acid Sample Preparation Methodology

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica