64012BC
MVP ICON® ATP Calibrator Set
MVP ICON®, ATP Luminometer Calibration
Sinônimo(s):
ATP Calibrator Set, ATP Measurement Calibration Kit, Quality Control ATP Calibrator
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Agency
EP
ISO
USP
prazo de validade
5 yr
Características
ready-to-use
fabricante/nome comercial
MVP ICON®
embalagem
set of calibrator rods
condição de armazenamento
protect from light (Keep in a tightlyclosed container, away from any light sources)
aplicação(ões)
food and beverages
compatibilidade
for use with MVP ICON instrument
temperatura de armazenamento
15-25°C
Categorias relacionadas
Descrição geral
MVP ICON® ATP Calibrator Set consists of two calibration devices (“rods”) that are used for performance verification and calibration of the MVP ICON® and MVP systems. The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low-energy ß-radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10 % of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five‐year life of the calibrator. The non‐luminescent black plastic calibrator provides a reliable low‐end or “dark” source reading.
Aplicação
MVP ICON® ATP Calibrator Set is used for performance verification and calibration of the MVP ICON® instrument for rapid monitoring of surface hygiene in the Food and Beverage industries.
Características e benefícios
- On-site calibration
- Satisfies HACCP and GMP requirements
- No need to send the equipment out to a 3rd party.
Componentes
- One luminescent calibrator
- One non-luminescent calibrator
Adequação
ATP Testing, Food Processing, HACCP Monitoring, Sanitation
Princípio
The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low energy ß radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10% of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five- year life of the calibrator. The non-luminescent black plastic calibrator provides a reliable low-end or “dark” source reading.
Método de teste
ATP Bioluminescence
Armazenamento e estabilidade
To ensure the stability and longevity of the luminescent calibrator, the following precautions must be taken:
- Limit Exposure to Light.
- Store the luminescent calibrator in the dark or weak ambient light.
- If the luminescent calibrator is exposed to bright light before use, insert it in the MVP ICON® or MVP and wait a minimum of 2 minutes before proceeding.
- The kit box provided is recommended as an appropriate dark storage.
- Do not expose to direct sunlight or intense artificial light before use.
Outras notas
Avoid crushing, cutting, or dropping the calibrators.
Informações legais
BioControl is a registered trademark of BioControl Systems, Inc.
MVP ICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Componentes do kit também disponíveis separadamente
Nº do produto
Descrição
SDS
- 72001SBCLuminescent Calibrator RodSDS
- Non Luminescent Calibrator Rod
Código de classe de armazenamento
10 - Combustible liquids
Classe de risco de água (WGK)
WGK 3
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica