KR75A05HH1
Opticap® XL5 Polygard® CR
inlet connection diam. 9/16 in., pore size 75.0 μm, cartridge nominal length 5 in. (12.5 cm)
Sinônimo(s):
Opticap XL5 Polygard-CR 75 μm 9/16 in. HB/HB
About This Item
Materiais
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Nível de qualidade
conformidade reg.
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
fabricante/nome comercial
Opticap®
Parâmetros
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.8 bar max. differential pressure (70 psid) at 20 °C
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure
Comprimento
21.6 cm (8.5 in.)
comprimento nominal do cartucho
5 in. (12.5 cm)
Diâmetro
10.7 cm (4.2 in.)
diâm. conexão de entrada
9/16 in.
L entrada para a saída
21.6 cm (8.5 in.)
diam. conexão de saída
9/16 in.
Impurezas
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
extraíveis gravimétricos
≤30 mg/capsule
matriz
Polygard®-CR
tamanho de poro
75.0 μm nominal pore size
75.0 μm pore size
entrada
sample type liquid
conector
inlet hose barb
14 mm (9/16 in.) inlet/outlet hose barb
outlet hose barb
Descrição geral
The KR75A05HH1 Opticap® XL5Polygard® CR features a pore size of 75.0 μm. This single layer emcapsulated depth filter has a hose barb inlet/outlet connection measuring 9/16 in. in diameter.
Opticap XL capsule filters eliminate the time and expense associated with assembling, cleaning, and validating stainless steel housings. The capsule patented design allows unparalleled thermal and hydraulic stress resistance, resulting in reliability, high confidence in the sterility process and improved cleanliness. The unique capsule design with Polygard® CR media minimizes hold-up volume and reduces production losses.
Características e benefícios
Embalagem
Outras notas
Nota de preparo
3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
Nota de análise
Informações legais
Exoneração de responsabilidade
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.