Buffer concentrate

(borate/hydrochloric acid), traceable to SRM of NIST and PTB for 500 ml buffer solution, pH 8.00 ± 0.02 (20°C) Titrisol®

Sinônimo(s):

Buffer concentrate for 500 ml buffer solution, pH 8.00 ± 0.02 (20°C)

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
12161705
NACRES:
NA.25

grau

analytical standard

Nível de qualidade

Agency

according to DIN 19266

linha de produto

Titrisol®

pH

8.00 (20 °C in H2O)

densidade

1.00 g/cm3 at 20 °C

aplicação(ões)

environmental
food and beverages
general analytical
industrial qc
pharmaceutical

formato

mixture

temperatura de armazenamento

15-25°C

Descrição geral

The Titrisol® reference buffer concentrate [borate/hydrochloric acid; pH=8.00±0.02 (20 °C)] is analyzed in the ISO/IEC 17025 accredited calibration laboratory with a combined glass electrode and 5-point calibration according to DIN 19268 against a certified primary standard reference material following DIN 19266.

The Titrisol® concentrated buffer material combines ease of use and maximum precision for the routine calibration and monitoring of pH instruments. To prepare the ready-to-use pH buffer solution, simply dilute the Titrisol® buffer concentrate.

Aplicação


  • Optimizing oral bioavailability in pharmaceuticals: Buffer concentrate is integral to the formulation of proniosomal drug delivery systems, as seen in the development of Irbesartan formulations where it enhances solubility and stability, facilitating improved bioavailability and therapeutic efficacy (Mujtaba et al., 2024).

  • Environmental remediation: In environmental science, buffer concentrate is used to adjust the pH of solutions, ensuring optimal conditions for the mediation of electron transfers in contaminant remediation processes, particularly in treatments involving heavy metals like chromium (Li and Zhang, 2024).

  • Biomedical research: Buffer concentrates are crucial for maintaining pH stability in biomedical experiments, such as studies on hemoglobin mass in response to apnea, which require precise control over biochemical conditions (Keeler et al., 2024).

  • Chemical analysis: In analytical chemistry, buffer concentrates are used to stabilize the environment during the voltammetric determination of dyes, ensuring accuracy and repeatability in the detection of chemical substances (Moulya et al., 2024).

Características e benefícios

  • Traceable to primary standard reference materials from NIST and PTB
  • Analytical standard Grade
  • Uncertainty data and traceability are documented in a comprehensive and batch-specific Certificate of Analysis.

Nota de análise

pH-value (20 °C): 8.00 ± 0.02
Measured after dilution to 500 ml with a combination glass electrode after multiple point calibration (according to DIN 19268) with reference materials for the preparation of standard buffer solutions according to DIN 19266.

Informações legais

Titrisol is a registered trademark of Merck KGaA, Darmstadt, Germany

padrão

Nº do produto
Descrição
Preços

Pictogramas

Health hazard

Palavra indicadora

Danger

Frases de perigo

Classificações de perigo

Repr. 1B

Código de classe de armazenamento

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Classe de risco de água (WGK)

WGK 1

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica