KGEPG3FBB1
Millipore Express® SHF, Capsule Opticap® XLT
Opticap® XLT 30, cartridge nominal length 30 in. (75 cm), filter diam. 19.8 cm (7.8 in.)
About This Item
Matériaux
polyester support
polypropylene device
polypropylene housing
polypropylene vent cap
polysulfone device
silicone seal
Niveau de qualité
Conformité réglementaire
meets FDA 21 CFR 177-182 (all component materials)
Stérilité
non-sterile
Mode de stérilisation compatible
gamma compatible
Gamme de produits
Opticap® XLT 30
Caractéristiques
hydrophilic
Fabricant/nom de marque
Millipore Express®
Paramètres
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 mbar max. differential pressure (15 psi) at 80 °C (Forward)
2.75 bar max. inlet pressure (40 psi) at 60 °C
2100 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 23 °C
5500 mbar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure
Technique(s)
sterile filtration: suitable
Largeur
7.8 in.
Longueur nominale des cartouches
30 in. (75 cm)
device L
87.2 cm (34.3 in.)
device size
30 in.
Diam. du filtre
19.8 cm (7.8 in.)
filter filtration area
1.71 m2
Impuretés
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
Matrice
Millipore Express® SHF
Dimension de pores
0.2 μm pore size
Point de bulle
≥4000 mbar (58 psig), air with water
Raccords
(25 mm (1 in.) Hose Barb Inlet and Outlet)
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Conditionnement
Notes préparatoires
3 autoclave cycles of 60 min at 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Remarque sur l'analyse
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Informations légales
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique