Skip to Content
Merck
  • Characterizing synthetic polymers and additives using new ionization methods for mass spectrometry.

Characterizing synthetic polymers and additives using new ionization methods for mass spectrometry.

Rapid communications in mass spectrometry : RCM (2014-04-25)
Tarick J El-Baba, Corinne A Lutomski, Beixi Wang, Sarah Trimpin
ABSTRACT

New inlet and vacuum ionization methods provide advantages of specificity, simplicity and speed for the analysis of synthetic polymers and polymer additives directly from surfaces such as fibers using mass spectrometry (MS) on different commercial mass spectrometers (Waters SYNAPT G2, Thermo LTQ Velos). We compare inlet ionization methods with the recently discovered vacuum ionization method. This method, termed matrix assisted ionization vacuum (MAIV), utilizes the matrix 3-nitrobenzonitrile (3-NBN) for the analysis of synthetic polymers and additives without additional energy input by simply exposing the matrix:analyte:salt to the vacuum of the mass spectrometer. Matrix:analyte:salt samples can be introduced while dry (surfaces, e.g. glass slides, pipet tips) or slightly wet (e.g. filter paper, pipet tips). Compounds ionized by these methods can be analyzed in both positive and negative detection modes through cationization or deprotonation, respectively. The dynamic range of the experiment can be enhanced, as well as structural analysis performed, by coupling the vacuum ionization method with ion mobility spectrometry mass spectrometry (IMS-MS) and tandem mass spectrometric (MS/MS) fragmentation. The specificity of 3-NBN matrix to ionize small and large nonvolatile analyte molecules by MAIV makes this matrix a good choice for observing low-abundance additives in the presence of large amounts of synthetic polymer using MS.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Sodium chloride, tablet
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Supelco
Sodium chloride, Pharmaceutical Secondary Standard; Certified Reference Material
SAFC
Sodium chloride solution, 5 M
Sigma-Aldrich
Lithium chloride, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99%
Sigma-Aldrich
Ethylene glycol, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Ethylene glycol, spectrophotometric grade, ≥99%
Sigma-Aldrich
Lithium chloride, ReagentPlus®, 99%
Sigma-Aldrich
Tetrahydrofuran, ACS reagent, ≥99.0%, contains 200-400 ppm BHT as inhibitor
Sigma-Aldrich
Lithium chloride, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, 99%
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Tetrahydrofuran, contains 200-400 ppm BHT as inhibitor, ACS reagent, ≥99.0%
Sigma-Aldrich
Acetic acid solution, suitable for HPLC
Supelco
Tetrahydrofuran, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Supelco
Lithium chloride solution, 1 M in ethanol
Sigma-Aldrich
Lithium chloride, powder, ≥99.98% trace metals basis
Sigma-Aldrich
3-Nitrobenzonitrile, 98%
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Sodium chloride, tested according to Ph. Eur.
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Poly(ethylene glycol) bis(2-ethylhexanoate), average Mn ~650
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl