GE28-9035-31
TempliPhi™ Sequence Resolver Kit
Cytiva 28-9035-31, sufficient for 200 reactions
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(1)
About This Item
Empfohlene Produkte
Form
liquid
Verwendung
sufficient for 200 reactions
Leistungsmerkmale
hotstart: no
Hersteller/Markenname
Cytiva 28-9035-31
Farbe
colorless
Versandbedingung
dry ice
Lagertemp.
−70°C
Allgemeine Beschreibung
illustra™ TempliPhi™ Sequence Resolver Kit uses the highly processive, strand-displacing Phi29 DNA polymerase and modified nucleotides to amplify circular templates for subsequent sequencing.
The kit can be used with both small (e.g., plasmids and M13) and large (fosmids and bacterial artificial chromosomes [BACs]) circular templates. The starting template for the reaction can be purified DNA, glycerol stock, liquid culture, or colonies. The reaction takes less than 20 min to prepare and after an overnight incubation at 10° C, it is ready to be used directly in sequencing applications with the sequencing chemistry of choice. A ten microliter (10 μ) reaction typically yields 1 μg of DNA in a standard overnight reaction.
The kit can be used with both small (e.g., plasmids and M13) and large (fosmids and bacterial artificial chromosomes [BACs]) circular templates. The starting template for the reaction can be purified DNA, glycerol stock, liquid culture, or colonies. The reaction takes less than 20 min to prepare and after an overnight incubation at 10° C, it is ready to be used directly in sequencing applications with the sequencing chemistry of choice. A ten microliter (10 μ) reaction typically yields 1 μg of DNA in a standard overnight reaction.
Leistungsmerkmale und Vorteile
- For the amplification of difficult templates for successful DNA sequencing.
- Solve the most common sequencing problems such as repeats, sequencing stops, and compressions with a single kit.
- Improve difficult template sequencing success with up to 820 bp Phred 20 read length.
- Cultureless preparation from bacterial colonies, glycerol stock or purified DNA; saves time and reagents.
- Easy-to-use kit requires only 20 min hands-on time.
- Amplified DNA can be directly used in sequencing reactions.
- illustra™ TempliPhi™ Sequence Resolver Kit produces exceptional sequencing results from difficult templates such as those with high GC content and secondary structures.
- The kit resolves most of the sequencing stops or gaps that routinely elude other commonly used finishing methods.
Lagerung und Haltbarkeit
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
S-re the kit at -70°C. The enzyme mix must be s-red at -70°C; all other components may be s-red at -20°C Thaw components on ice and maintain at 0°C - 4°C during handling
Hinweis zur Analyse
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Rechtliche Hinweise
TempliPhi
On packaging and insert for kits:
For use only as licensed by Qiagen GmbH. and Cytiva. The Phi 29 DNA polymerase may not be re-sold or used except in conjunction with the other components of this kit. See US patent numbers 5,854,033, 6,124,120, 6,143,495, 6,323,009, 5,198,543, 5,576,204, and their equivalents in other countries.
On container:
Subject to proprietary rights of Cytiva. May not be re-sold or used except with the other components of this kit. See US patent numbers 5,576,204, and their equivalents in other countries.
On packaging and insert for kits:
For use only as licensed by Qiagen GmbH. and Cytiva. The Phi 29 DNA polymerase may not be re-sold or used except in conjunction with the other components of this kit. See US patent numbers 5,854,033, 6,124,120, 6,143,495, 6,323,009, 5,198,543, 5,576,204, and their equivalents in other countries.
On container:
Subject to proprietary rights of Cytiva. May not be re-sold or used except with the other components of this kit. See US patent numbers 5,576,204, and their equivalents in other countries.
TempliPhi is a trademark of Cytiva
illustra is a trademark of Cytiva
Lagerklassenschlüssel
12 - Non Combustible Liquids
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.