Direkt zum Inhalt
Merck

F-017

Supelco

(±)-Flecainide solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C17H20F6N2O3
CAS-Nummer:
Molekulargewicht:
414.34
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

certified reference material

Form

liquid

Leistungsmerkmale

Snap-N-Spike®/Snap-N-Shoot®

Verpackung

ampule of 1 mL

Hersteller/Markenname

Cerilliant®

Konzentration

1.0 mg/mL in methanol

Methode(n)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

Anwendung(en)

clinical testing

Format

single component solution

Lagertemp.

−20°C

SMILES String

O=C(NCC1CCCCN1)C2=CC(OCC(F)(F)F)=CC=C2OCC(F)(F)F

InChI

1S/C17H20F6N2O3/c18-16(19,20)9-27-12-4-5-14(28-10-17(21,22)23)13(7-12)15(26)25-8-11-3-1-2-6-24-11/h4-5,7,11,24H,1-3,6,8-10H2,(H,25,26)

InChIKey

DJBNUMBKLMJRSA-UHFFFAOYSA-N

Angaben zum Gen

human ... SCN5A(6331)

Allgemeine Beschreibung

Flecainide, marketed under trade names such as Almarytm, Apocard, Ecrinal®, and Flécaine, is a class Ic antiarrhythmic drug used to prevent and treat a variety of cardiac arrhythmias. This Certified Spiking Solution® is suitable for use as a starting material in the preparation of calibrators, controls, or linearity standards in flecainide therapeutic drug monitoring methods by LC/MS or LC that ensure patients remain within the drug′s narrow therapeutic range.

Rechtliche Hinweise

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Ecrinal is a registered trademark of Laboratoires Asepta Corporation Monaco
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Zielorgane

Eyes,Central nervous system

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 2

Flammpunkt (°F)

49.5 °F - closed cup

Flammpunkt (°C)

9.7 °C - closed cup


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Heather Ellsworth et al.
Pacing and clinical electrophysiology : PACE, 36(3), e87-e89 (2012-08-14)
Flecainide is a Vaughan Williams Class Ic antidysrhythmic associated with PR, QRS, and QTc prolongation on the electrocardiogram and development of life-threatening cardiac toxicity in overdose. The cornerstone of treatment is fluid resuscitation and the administration of magnesium and sodium
[Flecainide intoxication].
Santiago Nogué et al.
Medicina clinica, 140(1), 46-46 (2012-10-03)
Joseph J Lynch et al.
Journal of cardiovascular pharmacology, 61(3), 226-232 (2012-11-29)
This study explored the intrinsic vasorelaxant and inotropic effects of the mixed potassium and sodium channel blocker atrial antiarrhythmic vernakalant and the class IC antiarrhythmic agent flecainide in human isolated subcutaneous resistance artery and in ventricular trabecular muscle preparations. At
Antiarrhythmic drug treatment after cardioversion of atrial fibrillation.
Marcelle D Smit et al.
Lancet (London, England), 380(9852), 1467-1467 (2012-10-30)
ECG diagnosis: flecainide toxicity.
Joel T Levis
The Permanente journal, 16(4), 53-53 (2012-12-20)

Artikel

For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.

The benefit of HILIC over traditional reversed-phase chromatography is two-fold for both sample introduction and analyte detection. First, the high acetonitrile concentration of HILIC mobile phases allows for direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. Second, the high acetonitrile content provides increased analyte response in positive ESI MS detection.

Verwandter Inhalt

HILIC mobile phases consist of a high composition of acetonitrile, which facilitates the direct analysis of precipitated plasma samples without the need for additional sample solvent exchange.

Chromatograms

application for HPLCapplication for HPLC

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.