M-137
Mycophenolic acid-d3 solution
100 μg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Productos recomendados
grade
certified reference material
Quality Level
form
liquid
feature
Snap-N-Spike®/Snap-N-Shoot®
packaging
ampule of 1 mL
manufacturer/tradename
Cerilliant®
concentration
100 μg/mL in acetonitrile
technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
application(s)
clinical testing
format
single component solution
storage temp.
−20°C
SMILES string
C/C(CCC(O)=O)=C\CC1=C(O)C2=C(COC2=O)C(C)=C1OC([2H])([2H])[2H]
InChI
1S/C17H20O6/c1-9(5-7-13(18)19)4-6-11-15(20)14-12(8-23-17(14)21)10(2)16(11)22-3/h4,20H,5-8H2,1-3H3,(H,18,19)/b9-4+/i3D3
InChI key
HPNSFSBZBAHARI-HZIIEIAOSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Application
- Ultra Performance Liquid Chromatography in Pharmacokinetics: A study utilizes ultra-performance liquid chromatography tandem mass spectrometry (UPLC/MS/MS) to determine mycophenolic acid in human plasma, enhancing drug monitoring in clinical settings. This technique offers high sensitivity and specificity, critical for therapeutic drug monitoring of immunosuppressants used in transplant medicine (Upadhyay et al., 2014).
- Comparative Methods for Immunosuppressant Monitoring: This research compares two rapid ultra-performance liquid chromatography/tandem mass spectrometry methods for therapeutic drug monitoring of immunosuppressants, including mycophenolic acid, against traditional immunoassay techniques. The study highlights the precision and faster turnaround times of UPLC/MS/MS methods, offering significant improvements in patient care management for those undergoing immunosuppressive therapy (Tszyrsznic et al., 2013).
Legal Information
Related product
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
35.6 °F - closed cup
flash_point_c
2 °C - closed cup
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Artículos
LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico